Water
Measurement1
gallon = 8.3 pounds 
1
cubic foot = 7.48 gallons = 62.4 pounds 
450
gallons per minute (gpm) =  
1
cubic foot per second (cfs) = 1 acre-inch per hour 
1
acre-inch = 27,000 gallons = 1 acre flooded 1 inch deep 
1
acre foot = 12 acre-inches = 43,560 cubic feet = 325,900 gallons 
1
gallon = 3.785 liters = 0.003785 cubic meters 
1
cubic meter = 1000 liters = 264.2 gallons  Pressure1
column of water 2.31 feet high exerts a pressure of 1 psi 
1
pound per square inch (psi) = 2.31 feet of water 
1
atmosphere = 14.7 psi = 33.95 feet of water 
1
inch of mercury (hg) = 1.13 feet of water 
psi
X 2.31 = feet of head 
Total
dynamic head (TDH) in feet includes: 
 pumping lift in feet 
 elevation change in feet 
 friction loss in feet 
 system operating pressure in feet 
TDH
= lift + elevation change + friction + pressure  HorsepowerWater
horsepower (WHP) - power required to lift a given quantity of water against
a given total dynamic head 
 | WHP
= | Q
X H 
3960 | Q
= flow rate (gpm) 
H
= total dynamic head (feet) |  
 Brake
horsepower (BHP) = required power input at the pump 
 | BHP
= | Q
X H 
3960
X E | Q
= flow rate (gpm) 
H
= total dynamic head (feet) 
E
= pump efficiency as a decimal 
(assume
.75 unless known) |  
 Water
ApplicationApplication
amount (H) inches: 
  |  | gpm 
450 | X | time |  | H
= | QT
= 
A | 
  |   |  | acres |  
 Q
= flow rate in acre-in./hr = gpm/450 
T
= length of application (hours 
A
= area irrigated in time T (acres)  Maximum
application rate for outer sprinklers of a center pivot: 
 | AR
= | Q
X 122.5 
R
x r | Q
= gpm of sprinkler system 
R
= length of center pivot (ft.) 
r
= radius of sprinkler heads at distance R 
AR
= application rate (inches/hr) |  
 Furrow
irrigation set size (acres):  No.
of rows X row width (feet) X row length (feet) 
43,560 |  
 Approximate
acreage covered by a pivot:  Radius
of pivot wetted area*,feet)2X
3.14 
43,560 |  
 *Wetted
radius includes radius of end gun  Flood
irrigation set time:  | T= | A
X D 
Q | T
= pumping time to flood a field to depth (D), in hours 
D
= depth of flood (inches)** 
A
= area of field to be flooded (acres) 
Q
= flow rate acre-inches/hr = GPM |  
 **Allow
for 1" additional water for seepage and other losses on newly flooded fields.
 Maximum
economical pipe flow capacities: 
RULE
OF THUMB - Based on maximum velocity of 5 ft/sec. |    |  
  |